NEW D-SNC-DY-00 EXAM ONLINE - STUDY D-SNC-DY-00 DEMO

New D-SNC-DY-00 Exam Online - Study D-SNC-DY-00 Demo

New D-SNC-DY-00 Exam Online - Study D-SNC-DY-00 Demo

Blog Article

Tags: New D-SNC-DY-00 Exam Online, Study D-SNC-DY-00 Demo, D-SNC-DY-00 Online Bootcamps, Exam D-SNC-DY-00 Forum, D-SNC-DY-00 Latest Test Prep

At ExamPrepAway, we understand the importance of flexibility and convenience in the learning experience. That's why we've designed our product to provide students with real EMC D-SNC-DY-00 questions they need to succeed, while also giving them the flexibility and convenience they need to fit their studies into their busy schedules. Free demos and up to 1 year of free practice material updates are also available at ExamPrepAway. Buy today and start your journey with actual Dell SONiC Deploy Exam (D-SNC-DY-00) exam dumps.

EMC D-SNC-DY-00 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Routing: Here, your routing knowledge will be tested, particularly in administering L3 IP addressing, configuring static routes, and understanding OSPF and BGP operations. As a cloud engineer, you must be adept at managing routing protocols and configurations to maintain efficient network traffic flow.
Topic 2
  • QoS: Your understanding of Quality of Service (QoS) is essential to become a certified Dell cloud engineer. The exam evaluates your ability to configure and verify QoS features. This section tests your ability to ensure optimal network performance, a vital skill in managing cloud environments where service quality is paramount.
Topic 3
  • SONiC Installation: Your proficiency in SONiC installation, upgrade, and downgrade methods will be tested in this Dell EMC D-SNC-DY-00 Exam Topic. You will need to install SONiC using both the ONIE manual and automatic methods. This topic measures your hands-on skills in managing SONiC installations efficiently.
Topic 4
  • VXLAN: This topic focuses on your ability to manage VXLAN operations, including configuring and verifying BGP EVPN with both Asymmetric and Symmetric IRB. Understanding VXLAN is essential for enabling scalable and efficient cloud networks, making this topic critical to your D-SNC-DY-00 exam success.

>> New D-SNC-DY-00 Exam Online <<

D-SNC-DY-00 PDF study guide & EMC D-SNC-DY-00 test-king

Our product boosts varied functions to be convenient for you to master the D-SNC-DY-00 training materials and get a good preparation for the exam and they include the self-learning function, the self-assessment function, the function to stimulate the exam and the timing function. We provide 24-hours online on D-SNC-DY-00 Guide prep customer service and the long-distance professional personnel assistance to for the client. If clients have any problems about our D-SNC-DY-00 study materials they can contact our customer service at any time.

EMC Dell SONiC Deploy Exam Sample Questions (Q23-Q28):

NEW QUESTION # 23
Create port channel 10 on interfaces Eth 1/11 and 1/12, so that it connects to an already configured switch. A server will be connected on Eth 1/1. Both the server and port channel need VLAN 1 untagged and only VLAN
10 tagged.
Complete the configuration on Switch A.

Answer:

Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to configure the required port channel and VLAN settings on Switch A:
* Enter Configuration Mode:
SwitchA# configure terminal
* Create Port Channel 10:
SwitchA(config)# interface port-channel 10
SwitchA(config-if-po10)# switchport mode trunk
SwitchA(config-if-po10)# switchport trunk native vlan 1
SwitchA(config-if-po10)# switchport trunk allowed vlan 1,10
* Assign Interfaces Eth 1/11 and Eth 1/12 to Port Channel 10:
SwitchA(config)# interface ethernet 1/11
SwitchA(config-if-eth1/11)# channel-group 10 mode active
SwitchA(config-if-eth1/11)# exit
SwitchA(config)# interface ethernet 1/12
SwitchA(config-if-eth1/12)# channel-group 10 mode active
SwitchA(config-if-eth1/12)# exit
* Configure Interface Eth 1/1 for Server Connection:
SwitchA(config)# interface ethernet 1/1
SwitchA(config-if-eth1/1)# switchport mode trunk
SwitchA(config-if-eth1/1)# switchport trunk native vlan 1
SwitchA(config-if-eth1/1)# switchport trunk allowed vlan 1,10
SwitchA(config-if-eth1/1)# end
* Save Configuration:
SwitchA# write memory
Comprehensive Detailed Step by Step Explanation with References:
* Enter Configuration Mode:
* Start by entering the global configuration mode to make changes to the switch configuration.
* Create Port Channel 10:
* Enter the port channel interface configuration mode using interface port-channel 10.
* Set the port channel to trunk mode with switchport mode trunk.
* Specify VLAN 1 as the native VLAN (untagged) using switchport trunk native vlan 1.
* Allow VLANs 1 and 10 on the trunk with switchport trunk allowed vlan 1,10.
* Assign Interfaces Eth 1/11 and Eth 1/12 to Port Channel 10:
* Enter interface configuration mode for ethernet 1/11 and ethernet 1/12.
* Assign each interface to port channel 10 using the channel-group 10 mode active command.
* Exit the interface configuration mode.
* Configure Interface Eth 1/1 for Server Connection:
* Enter interface configuration mode for ethernet 1/1.
* Set the interface to trunk mode with switchport mode trunk.
* Specify VLAN 1 as the native VLAN using switchport trunk native vlan 1.
* Allow VLANs 1 and 10 on the trunk with switchport trunk allowed vlan 1,10.
* Exit the configuration mode.
* Save Configuration:
* Ensure the configuration is saved so it persists after a reboot using the write memory command.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure a port channel and VLAN settings on Switch A to meet the specified requirements for server and trunk connections.


NEW QUESTION # 24
Which two things does the no vrrp 100 address-family ipv6 command delete?

  • A. Address-family
  • B. Interface
  • C. Authentication
  • D. Identifier
  • E. Version

Answer: A,D

Explanation:
The no vrrp 100 address-family ipv6 command deletes the VRRP (Virtual Router Redundancy Protocol) identifier (A) and the address-family configuration (D) for VRRP group 100. This effectively removes the VRRP configuration for the specified address family.
References:
* Dell Technologies SONiC documentation
* VRRP Configuration Guide


NEW QUESTION # 25
What are two characteristics of route maps in Enterprise SONIC?

  • A. The permit or deny clause In route maps permits or rejects the matching routes from being redistributed.
  • B. Route-map names are not case-sensitive.
  • C. Each route map clause has the type values of Match. Set. and Act.
  • D. They are a series of commands that contain a matching criterion and action.

Answer: A,D

Explanation:
Route maps in Enterprise SONIC are used for controlling and modifying routing information. They contain a series of commands with matching criteria and actions. The permit or deny clause within route maps determines whether the matching routes are permitted or denied from being redistributed.
References:
* Dell Technologies SONiC Route Map Configuration Guide
* Dell Networking Configuration Guide


NEW QUESTION # 26
Which three actions are required to route traffic sourced from voice servers to a dedicated Internet link''

  • A. Create a class-map and attach that ACL.
  • B. Create a class-map and attach an ACL with the IP of the next-hop to it.
  • C. Create an ACL that selects IPs of voice servers
  • D. Attach a policy to the egress interface
  • E. Create a policy-map and attach the configured class-map and set the next-hop IP

Answer: C,D,E

Explanation:
To route traffic from voice servers to a dedicated Internet link, the following steps are necessary:
* Create an ACL that selects IPs of voice servers (B): This ACL will match the traffic coming from the specified IP addresses of the voice servers.
* Create a policy-map and attach the configured class-map and set the next-hop IP (D): The policy-map will use the class-map to identify the voice server traffic and then set the next-hop IP for routing.
* Attach a policy to the egress interface (C): The policy-map must be applied to the egress interface to ensure that the traffic is routed correctly.
References:
* Dell SONiC QoS Configuration Guide
* Dell Technologies InfoHub
Feel free to refer to the Dell SONiC documentation and Dell Technologies InfoHub for more detailed explanations and additional context.


NEW QUESTION # 27
VLAN 40 is configured in Switch A with an anycast-address of 192.168.40.254/24. The ARP neighbor suppression is enabled. Use the simulator to create a VTEP named vtep1 and assign an IP address of
10.10.10.1. Map the VNI 400 to VLAN 40.

Answer:

Explanation:
see the explanation for all step by step solution with all explanation.
Explanation:
Here are the steps to create the VTEP and map the VNI to the VLAN:
* Enter Configuration Mode:
SwitchA# configure terminal
* Create VTEP Interface:
SwitchA(config)# interface vtep1
SwitchA(config-if-vtep1)# ip address 10.10.10.1/24
SwitchA(config-if-vtep1)# exit
* Map VNI 400 to VLAN 40:
SwitchA(config)# vlan 40
SwitchA(config-vlan)# vn-segment 400
SwitchA(config-vlan)# exit
* Enable ARP Neighbor Suppression:
SwitchA(config)# interface Vlan40
SwitchA(config-if-Vlan40)# ip address 192.168.40.254/24
SwitchA(config-if-Vlan40)# vxlan arp-suppression
SwitchA(config-if-Vlan40)# exit
* Save Configuration:
SwitchA# write memory
* Enter Configuration Mode:
* Begin by entering the global configuration mode to make changes to the switch configuration.
* Create VTEP Interface:
* Enter the interface configuration mode for the VTEP interface named vtep1 using interface vtep1.
* Assign the IP address 10.10.10.1/24 to the VTEP interface using the ip address command.
* Exit the interface configuration mode.
* Map VNI 400 to VLAN 40:
* Enter the VLAN configuration mode for VLAN 40 using vlan 40.
* Map the VNI 400 to VLAN 40 using the vn-segment 400 command.
* Exit the VLAN configuration mode.
* Enable ARP Neighbor Suppression:
* Enter the interface configuration mode for VLAN 40 using interface Vlan40.
* Assign the anycast IP address 192.168.40.254/24 to the VLAN interface using the ip address command.
* Enable ARP neighbor suppression using the vxlan arp-suppression command.
* Exit the interface configuration mode.
* Save Configuration:
* Save the configuration to ensure the changes persist after a reboot using the write memory command.
References:
* Dell Technologies Networking - SONiC
* Dell Enterprise SONiC Deployment Guide
These steps provide a comprehensive guide to configure a VTEP and map the VNI to VLAN 40 on Switch A, ensuring the specific requirements for IP addressing and ARP neighbor suppression are met.


NEW QUESTION # 28
......

We will be happy to assist you with any questions regarding our products. Our D-SNC-DY-00 practice exam ExamPrepAway helps to prepare applicants to practice time management, problem-solving, and all other tasks on the standardized D-SNC-DY-00 Exam and lets them check their scores. The D-SNC-DY-00 results help students to evaluate their performance and determine their readiness without difficulty.

Study D-SNC-DY-00 Demo: https://www.examprepaway.com/EMC/braindumps.D-SNC-DY-00.ete.file.html

Report this page